Search results for "Resonance line"

showing 5 items of 5 documents

Electron paramagnetic resonance line shape investigation of the Si-29 hyperfine doublet of the E'γ center in a-SiO2

2007

We report an experimental study by electron paramagnetic resonance (EPR) spectroscopy of the E′γ center and of its hyperfine structure, consisting in a pair of lines split by 42 mT. Our results show that two types of E′γ centers can be distinguished on the basis of the EPR line shapes of their main resonance line and hyperfine structure. (© 2007 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)

Electron nuclear double resonanceChemistrySettore ING-IND/20 - Misure E Strumentazione NucleariSettore FIS/01 - Fisica SperimentaleCenter (category theory)radiazione gammaCondensed Matter Physicslaw.inventionNuclear magnetic resonanceelectron paramagnetic resonancelawAtomic physicsSpectroscopyElectron paramagnetic resonanceResonance lineHyperfine structureLine (formation)
researchProduct

Orientation of199mHg by optical pumping detected by ?-radiation anisotropy

1975

199mHg was produced and mass separated at the ISOLDE facility (CERN). Nuclear orientation achieved by optical pumping via the resonance line 6s21S0→6s6p3P1,λ=2537A was monitored by means of the anisotropy of theγ-radiation emitted in the cascade199mHg(I=13/2+) $${}^{199m}Hg(I = 13/2^ + )\xrightarrow[{M4}]{}{}^{199*}Hg(I = 5/2^ - )\xrightarrow[{E2}]{}{}^{199}Hg(I = 1/2^ - ).$$ 199*Hg(I=5/2−)199Hg(I=1/2−).

Optical pumpingOrientation (vector space)PhysicsNuclear and High Energy Physicsγ radiationIsotopic shiftAnalytical chemistryNuclear fusionElementary particleAtomic physicsAnisotropyResonance lineZeitschrift f�r Physik A Atoms and Nuclei
researchProduct

Gamma ray induced 11.8 mT ESR doublet in natural silica

1998

Abstract We report electron spin resonance (ESR) measurements in natural and synthetic vitreous SiO2 samples irradiated by γ rays. An 11.8 mT doublet, asymmetrically centered on the resonance line of the E′ center, was detected only in natural samples. The intensity of this doublet as a function of γ exposure tends to saturate for doses as low as 0.2 Mrad and is not related to the growth kinetics of the E′ centers. Photoluminescence (PL) measurements on the same samples have shown that two emissions at 3.15 and 4.26 eV bleach with the same kinetics as does the 11.8 mT doublet on increasing the γ ray dose. We tentatively suggest the presence of a conversion mechanism, activated by γ irradiat…

PhotoluminescenceGrowth kineticsChemistryKineticsGamma rayAnalytical chemistryCondensed Matter Physicsγ irradiationElectronic Optical and Magnetic Materialslaw.inventionNuclear magnetic resonancelawMaterials ChemistryCeramics and Compositessense organsIrradiationElectron paramagnetic resonanceResonance lineJournal of Non-Crystalline Solids
researchProduct

Collinear laser spectroscopy of high-energy Li-like11B beam

1997

As part of the RIKEN RIBF (RI beam factory) program, high-resolution x-ray spectroscopy for highly-charged radioactive isotope beams, is proposed in order to make a systematic study of the mean-square nuclear charge radii and moments of short lived radioactive isotopes far from the line of stability. To examine the feasibility of the experiment, we are now performing a test experiment using a laser beam and Li-like ion beams from RIKEN ring cyclotron. The D1 resonance line of a 11B2+ beam was clearly observed for the first time.

PhysicsHigh energyCyclotronCondensed Matter PhysicsAtomic and Molecular Physics and OpticsEffective nuclear chargeIonlaw.inventionlawPhysics::Accelerator PhysicsAtomic physicsNuclear ExperimentSpectroscopyResonance lineMathematical PhysicsBeam (structure)Line (formation)Physica Scripta
researchProduct

Measurement and interpretation of the polarization of the x-ray line emission of heliumlike Fe XXV excited by an electron beam

1996

The linear polarization of the 1s2p${\mathrm{}}^{1}$${\mathit{P}}_{1}$\ensuremath{\rightarrow}1${\mathit{s}}^{2}$${\mathrm{}}^{1}$${\mathit{S}}_{0}$ resonance line, the 1s2p${\mathrm{}}^{3}$${\mathit{P}}_{1,2}$\ensuremath{\rightarrow}1${\mathit{s}}^{2}$${\mathrm{}}^{1}$${\mathit{S}}_{0}$ intercombination lines, and the 1s2s${\mathrm{}}^{3}$${\mathit{S}}_{1}$\ensuremath{\rightarrow}1${\mathit{s}}^{2}$${\mathrm{}}^{1}$${\mathit{S}}_{0}$ forbidden line was measured in heliumlike Fe XXV excited near threshold by a monoenergetic electron beam. The measurement was carried out with a high-resolution x-ray spectrometer employing a set of two analyzing crystals that acted as polarizers by selectivel…

PhysicsNear thresholdExcited stateCathode rayX-rayAtomic physicsAstrophysicsPolarization (waves)Forbidden mechanismResonance lineX ray spectraMicrophysicsAtomic and Molecular Physics and OpticsPhysical Review A
researchProduct